What is GLP-2TZ?
GLP-2TZ is a synthetic 39 residue peptide carrying a fatty diacid side chain, supplied as a lyophilized powder for laboratory research. It is a dual agonist at the glucose-dependent insulinotropic polypeptide (GIP) receptor and the glucagon-like peptide-1 (GLP-1) receptor, and is handled in the laboratory as a reference material for receptor pharmacology and analytical work.
GLP-2TZ structure and sequence
The sequence is Tyr-Aib-Glu-Gly-Thr-Phe-Thr-Ser-Asp-Tyr-Ser-Ile-Aib-Leu-Asp-Lys-Ile-Ala-Gln-Lys-Ala-Phe-Val-Gln-Trp-Leu-Ile-Ala-Gly-Gly-Pro-Ser-Ser-Gly-Ala-Pro-Pro-Pro-Ser-NH2, with the lysine at position 20 acylated through a gamma-glutamic acid and oxyethylene linker to a C20 fatty diacid. Molecular weight 4813.5 Da. Analytically it behaves differently from a short peptide: the lipid chain makes it strongly retained on reversed phase columns, and in electrospray mass spectrometry it appears as a series of multiply charged ions that are deconvoluted to give the intact mass.
Where this material appears in the literature
GLP-2TZ has an extensive published literature, preclinical and clinical, as a dual GIP and GLP-1 receptor agonist. DNApeptidesElite supplies this material for in vitro and analytical work, such as receptor binding, signaling assays and method development, and makes no claim about what it does in any living subject.
Related material in the catalog
GLP-2TZ is held under Metabolic Research alongside GLP-1SG. Both are lipidated incretin analogs, but they differ in receptor profile and length: GLP-2TZ is a 39 residue peptide studied as a dual GIP and GLP-1 receptor agonist, while GLP-1SG is a 31 residue peptide studied as a selective GLP-1 receptor agonist.
Analysis and certification
Every lot is analyzed by an independent laboratory before release, using RP-HPLC for purity and LC-MS for identity confirmation. The certificate of analysis is published against the lot number rather than against the product page, so the document you read is the document for the vial you receive. The lot number printed on the vial label is the link between the two, and every certificate can be found in our COA library.
Purity specification
Lots are released against a ≥99% purity specification, determined by RP-HPLC peak area. A specification is a release threshold, not a description of every lot. The measured figure for the lot you receive is stated on its certificate of analysis and may sit above the specification.
Where a measured figure and the specification differ, the certificate is the record that applies to your material. Analytical figures relate to the lot they are published against and carry no implication of suitability for any purpose beyond laboratory research.
Research use only
DNApeptidesElite supplies this material as a reference standard for laboratory research. It is not supplied for any use in humans or animals, it is not a drug, dietary supplement, food or cosmetic, and nothing on this page describes or implies any such use. Sale is restricted to persons aged 21 or over who are qualified researchers or who purchase on behalf of a research institution, laboratory or business.
| Compound |
GLP-2TZ |
| Class |
Synthetic lipidated peptide |
| Amino acids |
39 |
| Sequence |
Tyr-Aib-Glu-Gly-Thr-Phe-Thr-Ser-Asp-Tyr-Ser-Ile-Aib-Leu-Asp-Lys-Ile-Ala-Gln-Lys-Ala-Phe-Val-Gln-Trp-Leu-Ile-Ala-Gly-Gly-Pro-Ser-Ser-Gly-Ala-Pro-Pro-Pro-Ser-NH2 |
| Modification |
Lys20 acylated with a C20 fatty diacid through a gamma-Glu and oxyethylene linker; C-terminal amide |
| Molecular formula |
C225H348N48O68 |
| Molecular weight |
4813.5 Da |
| CAS number |
2023788-19-2 |
| Appearance |
White to off white lyophilized powder |
| Purity specification |
≥99% |
| Purity method |
RP-HPLC |
| Identity method |
LC-MS |
| Solubility |
Soluble in aqueous buffer at neutral to slightly basic pH |
| Labeled quantity |
10 mg per vial |
Characterization. Values above describe the compound as supplied. The figures for the lot you receive, including measured purity, are stated on its certificate of analysis.
How this material is tested
Two separate analyses are carried out on every lot before release, and both appear on the certificate.
- RP-HPLC, for purity. Reversed phase high performance liquid chromatography separates the material by hydrophobicity. The main peak is integrated against total peak area, and that ratio is the purity figure reported on the certificate.
- LC-MS, for identity. Liquid chromatography coupled to mass spectrometry confirms that the mass of the main peak matches the expected mass for the compound, which is what distinguishes the correct sequence from a closely related one.
A complete certificate carries the compound name, the lot number, the test date, the method, the measured purity and the name of the laboratory. If any of those is missing, or the lot number on the vial does not match the certificate, contact us before using the material.
Storing GLP-2TZ
Lyophilized material is shipped cold and should be moved into freezer storage on arrival. Store the sealed vial dry at −20°C or below, protected from light and moisture. Returned promptly to those conditions, the dry solid is the most stable form this material takes.
Preparing stock solutions
Prepare stock solutions in an aqueous buffer at neutral to slightly basic pH, at a concentration suited to your assay, expressed in mg/mL. Allow the vial to reach room temperature before opening, add solvent down the vial wall rather than directly onto the solid, and let the material dissolve without vigorous agitation. Dissolution in unbuffered water can be slow because the molecule carries several acidic groups; a dilute buffer near pH 7 to 8 assists. Lipidated peptides adsorb to some plastics, so low binding tubes are preferable for dilute solutions.
Solutions are less stable than the lyophilized solid. Prepare close to the point of use, hold at 2 to 8°C for short periods only, and aliquot before freezing so that repeated freeze and thaw cycles are avoided.
On arrival
Check that the vial is intact and sealed, that the compound name and labeled quantity match your order, and that the lot number on the label matches the certificate published for it. If anything does not match, or the packaging has clearly failed in transit, contact us before using the material. Problems visible on arrival should be reported within 7 days so that a carrier claim remains possible.
Handling and disposal
Assess the hazards of this material before handling it and use appropriate controls and protective equipment. It has not been characterized toxicologically and should be treated as potentially hazardous. Anyone handling it should be trained for the work.
Dispose of unused material, vials and packaging lawfully and in line with your institution's waste procedures.
Record keeping
Record the lot number in your notes at the point of first use, alongside the date the vial was opened and the concentration of any stock prepared. Certificates are published against the lot number rather than the product, so the lot number is the only reliable link between your results and the analytical data for the material that produced them. If a question arises about a result months later, that link is what keeps the work auditable.